Diagnostic Imaging, Medical Supply, Medrad Syringe manufacturer / supplier in China, offering Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe, Medrad Bayer Stellant CT Contrast Media Medium Injector Syringes with Ce ISO FDA, 150ml Medrad Imaxeon Avidia Angiography Contrast Injector Syringes for Single Use and so on.

(/ )

Supplier Homepage Product CT/MRI/DSA Syringe & Accessories Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe

Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe

FOB Price: Get Latest Price
Min. Order: 1,000 Pieces
Port: Shenzhen, China
Production Capacity: 150, 000 PCS Per Month
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: 100101
  • Material: Plastic
  • Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
  • Group: Adult
  • Product Name: High Pressure Angiographic Syringe
  • Original Material: Pet/PP/ABS/ Rubber
  • Disposable: Yes
  • Price: EXW
  • Volume: 200ml
  • Transport Package: 50 Sets Per Box
  • HS Code: 9018310000
  • Type: Radiology Medical Material
  • Certification: CE, SGS, FDA, ISO13485, ISO9001
  • Quality Guarantee Period: 3years
  • Logo Printing: With Logo Printing
  • Scope of Syringe: CT/MRI/Angiographic Syringe
  • Applicable to Injector: CT Syringes
  • OEM: Yes
  • Weight: 10kg Per Case
  • Trademark: BOON
  • Origin: Shenzhen
Product Description

Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe

diagnostic imaging medical supply medrad 200ml CT /MRI/ANGIO injector compatible syringe 
Specification:
1.CT syringe :  (Single) 1-200ml syringe , 1-1500mm connecting tube , 1-J tube    50sets per case 
             (Dual)   2- 200ml syringe, 1-1500mm Y (T) connecting tube, 2-J tube 20sets per case
2.MR syringe :2-65ml syringe, 1-2500mm T type connecting tube , 2 - Spikes       50sets per case
             2-60ml syringe , 1-2500mm T type connecting tube , 2 - Spikes      50sets per case
3.DSA syringe: 1-150ml syringe , 1-J tube                                       50sets per case
Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible SyringeDiagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible SyringeDiagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe
Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe

Certification 
Diagnostic Imaging Medical Supply Medrad 200ml CT /MRI/Angio Injector Compatible Syringe


Sea Freight 
 Reference Data (Sea Freight)
Container20GP40GP40HQ45HQ
Area(M3)25546886
Quantity(Case)260440550700

Compatibility between syringes and injectors
Model (Syringe)Volume (ml)Compatible Angiographic Injector
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following MEDRAD Injector models
100101200mlMCT & MCT plus CT, Vistron CT, En Vision CT
100103200mlMedrad Stellant-S
100113200/200mlMadrad Stellant-D(Dual)
20010165/65mlSpectris
20010265/115mlSolaris
300101150mlMark V
300105130mlMark III & Mark IV
300108150mlMark VII
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following LIEBEL - FLARSHEIM Injector models
100104200mlCT 9000 & CT9000 ADV Optivantage
100114200/200mlCT 9000 & CT9000 ADV Optivantage(Dual)
20010360/60mlOptistar LE, Elite
300103150mlILLUMENA
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following EZEM Injector models
100111200mlEmpower CT
100121200/200mlEmpower CT (Dual)
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following NEMOTO Injector models
100108200mlA-60 CT
100109100mlA-25 CT
100118200/200mlA-60 CT (Dual)
100119100/100mlA-25CT (Dual)
20010460ml/60mlSonic Shot 50
300102125ml120S
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following MEDTRON Injector models
100112200ml Medtron
20010560/60mlMedtron(Dual)
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following IMAXEON Injector models
100110200ml Imaxeon Salient
100120200mlImaxeon Salient (Dual)
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following others injector models
100102200mlCHINA SINO-D-S
100105200ml CHINA ANKE ASA200
100115200/200mlCHINA SINO-D (Dual)
100106200mlCHINA SEACROWN ZENITH-C20
100116200/200mlCHINA SEACROWN ZENITH -C22 (Dual)
100107100mlCHINA SEACROWN ZENITH-C11/C10
100117100/100mlCHINA SEACROWN ZENITH-C11 (Dual)
20010665/65mlCHINA SEACROWN ZENITH-C60 (Dual)
20010765mlCHINA SEACROWN ZENITH-C60
300104150mlCHINA SEACROWN ZENITH-H15

Instructions for Use
Syringe Filling
1.NOTE: One person should fill and arm the injector. If you must change the injector operator, be certain that the second operator verifies that the syringe is properly filled and that any air is eliminated.
2.Tilt the injector head (or the syringe interface module) up.
3.Advance the plunger to full forward position. 
4.Remove the protective cover from the syringe luer tip and attach a sterile filling device onto the tip of the syringe. Fill straw, or spike.
5.Transfer the contrast media into the syringe by one of following methods:
6.Fill Straw: raise the contrast bottle until the Fill Straw is fully inserted. The end of the Fill Straw should be near the bottom of the contrast bottle.
7.Spike: prepare the bottle or container of contrast and/or saline solution. Push the bottle or bag onto the Filling Device until the seal is punctured.
8.NOTE: Use Fill Straw or equivalent device to reduce the volume and size of air bubbles drawn into the syringe during filling. It is more difficult to remove the air bubbles if you use smaller diameter tubes, such as catheter-over-needle, or a tube longer than 10 in.(25cm.)
9.Aspirate contrast media into the syringe.
10.If the syringe has dot indicators use them to help you detect the presence of contrast media in the syringe. Verify that the Syringe disposable dot indicators are round in the filled portion of the syringe. The rounded shape of the dot indicators varies according to the type of contrast media, but an oblong shape indicates the presence of air. Rounded dot indicators do not indicate the total absence of air bubbles in the syringe tip.
* Refer to the injector operation manual for further instructions.
Expelling Air & Attaching the Connector Tubing
1.After you fill the syringe, you must expel all air from the syringe and then attach the connector tubing. To do so:
2.Remove the filling device and expel air from the syringe. Do not hit the syringe to remove air bubbles. Reverse the plunger 3 to 5 ml, then, if applicable, rock the injector head on the pivot to dislodge the bubbles. Expel the remaining air.
3.If you are using a Y low pressure connector tubing, attach shorter side of the Y to the contrast syringe and the longer side of the Y to the saline syringe. Do not reverse the piston plunger after you have attached the tubing. 
4.Verify that the tubing is not kinked or obstructed.
5.(If your injector does not have a manual knob, proceed to Step 6.) Use the manual knob to advance the syringe plunger to provide 
6.Prime the connector tubing and make certain that the air is expelled. 
7.Verify that all the air has been expelled from the syringe and fluid path. 
8.Attach the connector tube to the vascular entry device.
9.Tilt the injector head (or syringe interface module) down. 
* Refer to the injector operation manual for further instructions.
Removing the Syringe
10.To detach the syringe when the procedure has been completed, Remove it from the injector head. Discard all used components.
* Refer to the injector operation manual for further instructions.
11.Check the integrity of each primary package before use!
12.Confirm syringe model and injector model compatibility per Table 1 above.
13.Remove the syringe from the package. Attach the syringe to the injector according to the injector instructions for use.
14.Use the injector to push the piston of the syringe to the front of the barrel.
15.Remove the sheath from the conical fitting. Assemble the J shape tube/ spike on the conical fitting of the syringe.
16.Draw the required contrast media or saline into the syringe at the lowest speed of the injector to prevent air leakage.
17.Remove the J shape tube/spike from the syringe; discard it per the hospital or local regulations. Do not reuse!
18.Remove the protective cap from the conical fitting of the high pressure tube. Attach the tube to the syringe.
19.Attach the I.V. catheter or contrast media catheter to the other conical fitting of the high pressure tube. 
20.Expel the air in the catheter and tube. 
21.Inject the contrast media or saline in accordance with the instruction for use of the injector.
22.After the injection, disconnect the I.V. catheter or contrast media catheter and the high pressure tube.  Remove the syringe from the injector. 
23.Discard the syringe, tube and catheter immediately per hospital or local regulations.

More information,please contact us kindly.
You Might Also Like
Send your message to this supplier
Avatar
Mr. Brant
Overseas Manager
*From:
To: Mr. Brant
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now