Boon Sterile Disposable 200ml High Pressure CT MRI Angiographic Syringe for America Hospital Supply

Type: Radiology Medical Material
Material: Plastic
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 3years
Group: Adult
Logo Printing: With Logo Printing
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
300000
Certification
CE, SGS, FDA, ISO13485, ISO9001
Product Name
High Pressure Angiographic Syringe
Scope of Syringe
CT/Mr/Angiographic Syringe
Original Material
Pet/PP/ABS/ Rubber
Applicable to Injector
Medrad /Lf/Ezem/Imaxeon/ Nemoto
Disposable
Yes
OEM
Yes
Price
EXW
Weight
10kg Per Case
Volume
200ml
Transport Package
50 Sets Per Box
Trademark
BOON
Origin
Shenzhen
HS Code
9018310000
Production Capacity
150, 000 PCS Per Month

Product Description



Boon sterile disposable  200ml high pressure ct mri angiographic syringe for America Hospital supply 
Specification:
1.CT syringe :  (Single) 1-200ml syringe , 1-1500mm connecting tube , 1-J tube                  50sets per case 
                           (Dual)   2- 200ml syringe, 1-1500mm Y (T) connecting tube, 2-J tube        20sets per case
2.MR syringe :2-65ml syringe, 1-2500mm T type connecting tube , 2 - Spikes                      20sets per case
                      2-60ml syringe , 1-2500mm T type connecting tube , 2 - Spikes                      20sets per case
3.DSA syringe: 1-200ml syringe , 1-J tube                                                                            50sets per case
Picture




Certification 


Sea Freight 
 Reference Data (Sea Freight)
Container 20GP 40GP 40HQ 45HQ
Area(M3) 25 54 68 86
Quantity(Case) 260 440 550 700

Compatibility between syringes and injectors
Model (Syringe) Volume (ml) Compatible Angiographic Injector
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following MEDRAD Injector models
100101 200ml MCT & MCT plus CT, Vistron CT, En Vision CT
100103 200ml Medrad Stellant-S
100113 200/200ml Madrad Stellant-D(Dual)
200101 65/65ml Spectris
200102 65/115ml Solaris
300101 150ml Mark V
300105 130ml Mark III & Mark IV
300108 150ml Mark VII
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following LIEBEL - FLARSHEIM Injector models
100104 200ml CT 9000 & CT9000 ADV Optivantage
100114 200/200ml CT 9000 & CT9000 ADV Optivantage(Dual)
200103 60/60ml Optistar LE, Elite
300103 150ml ILLUMENA
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following EZEM Injector models
100111 200ml Empower CT
100121 200/200ml Empower CT (Dual)
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following NEMOTO Injector models
100108 200ml A-60 CT
100109 100ml A-25 CT
100118 200/200ml A-60 CT (Dual)
100119 100/100ml A-25CT (Dual)
200104 60ml/60ml Sonic Shot 50
300102 125ml 120S
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following MEDTRON Injector models
100112 200ml Medtron
200105 60/60ml Medtron(Dual)
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following IMAXEON Injector models
100110 200ml Imaxeon Salient
100120 200ml Imaxeon Salient (Dual)
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following others injector models
100102 200ml CHINA SINO-D-S
100105 200ml CHINA ANKE ASA200
100115 200/200ml CHINA SINO-D (Dual)
100106 200ml CHINA SEACROWN ZENITH-C20
100116 200/200ml CHINA SEACROWN ZENITH -C22 (Dual)
100107 100ml CHINA SEACROWN ZENITH-C11/C10
100117 100/100ml CHINA SEACROWN ZENITH-C11 (Dual)
200106 65/65ml CHINA SEACROWN ZENITH-C60 (Dual)
200107 65ml CHINA SEACROWN ZENITH-C60
300104 150ml CHINA SEACROWN ZENITH-H15

Instructions for Use
Syringe Filling
1.NOTE: One person should fill and arm the injector. If you must change the injector operator, be certain that the second operator verifies that the syringe is properly filled and that any air is eliminated.
2.Tilt the injector head (or the syringe interface module) up.
3.Advance the plunger to full forward position. 
4.Remove the protective cover from the syringe luer tip and attach a sterile filling device onto the tip of the syringe. Fill straw, or spike.
5.Transfer the contrast media into the syringe by one of following methods:
6.Fill Straw: raise the contrast bottle until the Fill Straw is fully inserted. The end of the Fill Straw should be near the bottom of the contrast bottle.
7.Spike: prepare the bottle or container of contrast and/or saline solution. Push the bottle or bag onto the Filling Device until the seal is punctured.
8.NOTE: Use Fill Straw or equivalent device to reduce the volume and size of air bubbles drawn into the syringe during filling. It is more difficult to remove the air bubbles if you use smaller diameter tubes, such as catheter-over-needle, or a tube longer than 10 in.(25cm.)
9.Aspirate contrast media into the syringe.
10.If the syringe has dot indicators use them to help you detect the presence of contrast media in the syringe. Verify that the Syringe disposable dot indicators are round in the filled portion of the syringe. The rounded shape of the dot indicators varies according to the type of contrast media, but an oblong shape indicates the presence of air. Rounded dot indicators do not indicate the total absence of air bubbles in the syringe tip.
* Refer to the injector operation manual for further instructions.
Expelling Air & Attaching the Connector Tubing
1.After you fill the syringe, you must expel all air from the syringe and then attach the connector tubing. To do so:
2.Remove the filling device and expel air from the syringe. Do not hit the syringe to remove air bubbles. Reverse the plunger 3 to 5 ml, then, if applicable, rock the injector head on the pivot to dislodge the bubbles. Expel the remaining air.
3.If you are using a Y low pressure connector tubing, attach shorter side of the Y to the contrast syringe and the longer side of the Y to the saline syringe. Do not reverse the piston plunger after you have attached the tubing. 
4.Verify that the tubing is not kinked or obstructed.
5.(If your injector does not have a manual knob, proceed to Step 6.) Use the manual knob to advance the syringe plunger to provide 
6.Prime the connector tubing and make certain that the air is expelled. 
7.Verify that all the air has been expelled from the syringe and fluid path. 
8.Attach the connector tube to the vascular entry device.
9.Tilt the injector head (or syringe interface module) down. 
* Refer to the injector operation manual for further instructions.
Removing the Syringe
10.To detach the syringe when the procedure has been completed, Remove it from the injector head. Discard all used components.
* Refer to the injector operation manual for further instructions.
11.Check the integrity of each primary package before use!
12.Confirm syringe model and injector model compatibility per Table 1 above.
13.Remove the syringe from the package. Attach the syringe to the injector according to the injector instructions for use.
14.Use the injector to push the piston of the syringe to the front of the barrel.
15.Remove the sheath from the conical fitting. Assemble the J shape tube/ spike on the conical fitting of the syringe.
16.Draw the required contrast media or saline into the syringe at the lowest speed of the injector to prevent air leakage.
17.Remove the J shape tube/spike from the syringe; discard it per the hospital or local regulations. Do not reuse!
18.Remove the protective cap from the conical fitting of the high pressure tube. Attach the tube to the syringe.
19.Attach the I.V. catheter or contrast media catheter to the other conical fitting of the high pressure tube. 
20.Expel the air in the catheter and tube. 
21.Inject the contrast media or saline in accordance with the instruction for use of the injector.
22.After the injection, disconnect the I.V. catheter or contrast media catheter and the high pressure tube.  Remove the syringe from the injector. 
23.Discard the syringe, tube and catheter immediately per hospital or local regulations.

More information,please contact us kindly.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
23600000 RMB
Plant Area
5000 square meters