• Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
  • Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
  • Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System

Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System

Type: Radiology Medical Material
Material: Plastic
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 3years
Group: Adult
Logo Printing: With Logo Printing
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
400102
Product Name
Boon 1800mm CT Connector Tubing
Scope
for CT Injection Procedure
Original Material
PVC Dehp /Totm/ABS
Applicable to Injector
Medrad /Lf/Ezem/Imaxeon/ Nemoto
Disposable
Yes
OEM
Acceptable
Check Valve
No Valve
Weight
13.5kg Per Carton
Luer Lock
6% International Luer Lock
Female/Male Connector
One Female/One Male
Max Pressure
350psi
Package
Blister Pack
Inner Diameter
1.85mm
Outer Diameter
3.25mm
Transport Package
400PCS Per Box
Specification
1500mm/1800mm
Trademark
BOON
Origin
Shenzhen
HS Code
9018310000
Production Capacity
150, 000 PCS Per Month

Product Description

Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
Description 

Boon Sterile CT coiled tubing used for Enhancing scan imaging, compatible with various different CT injectors. 
helping doctors find lesions more clearly and quickly. Contrast agents and saline are injected through various CT contrast media injectors. Mainly used in the hospital radiology department and medical imaging department.

Boon Angiographic syringes have covered the world's main popular contrast media injectors models, such as Medrad, LF, Medtron, Nemoto, Bracco, SINO, SEACROWN.

Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
Specification
   
 1.5m (1.8m) is for option   400pcs per case
Pressure : 300psi/350psi
19 400102 300psi 1800mm Y Coiled Tube without Valve
20 400102A 300psi 1800mm Y Coiled Tube
with one Valve
21 400102B 300psi 1800mm Y Coiled Tube 
22 400102D 300psi 1500mm Y Coiled Tube without Valve
23 400102E 300psi 1500mm Y Coiled Tube
with one Valve
24 400102F 300psi 1500mm Y Coiled Tube 
25 400102G 300psi 100mm Y Coiled Tube 
26 400102H 300psi 300mm Y Coiled Tube 
27 400102J 300psi 1000mm Y Coiled Tube 
28 400102K 300psi 1000mm Y Coiled Tube
with one Valve
29 400102M 300psi 1200mm Y Coiled Tube 
30 400102N 300psi 2000mm Y Coiled Tube 
31 400102L 300psi 600mm Y Coiled Tube without Valve
32 400102Y 350psi 1800mm Y Coiled Tube without Valve
33 400102P 350psi 1800mm Y Coiled Tube
with one Valve
34 400102Q 350psi 1800mm Y Coiled Tube 
35 400102R 350psi 1500mm Y Coiled Tube without Valve
36 400102S 350psi 1500mm Y Coiled Tube
with one Valve
37 400102T 350psi 1500mm Y Coiled Tube 
38 400102W 350psi 1000mm Y Coiled Tube 
39 400102X 350psi 1200mm Y Coiled Tube 
                                                                        
Quality Control 

Boon high-pressure syringes strictly implement ISO9001 and ISO13485 quality management systems and are produced in 100,000-level purification workshops. Quality is the life of an enterprise. Boon is always following the quality policy of "Pursuing Product Excellence Ensuring Public Health" 
Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System

Package
 
 Reference Data (Sea Freight)
Container 20GP 40GP 40HQ 45HQ
Area(M3) 25 54 68 86
Quantity(Case) 260 440 550 700




Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
Boon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection SystemBoon 350psi 1800mm Popular Coiled Extension Tubing with Luer Lock with Y Connector for CT Injection System
Instructions for Use
Syringe Filling
1.NOTE: One person should fill and arm the injector. If you must change the injector operator, be certain that the second operator verifies that the syringe is properly filled and that any air is eliminated.
2.Tilt the injector head (or the syringe interface module) up.
3.Advance the plunger to full forward position. 
4.Remove the protective cover from the syringe luer tip and attach a sterile filling device onto the tip of the syringe. Fill straw, or spike.
5.Transfer the contrast media into the syringe by one of following methods:
6.Fill Straw: raise the contrast bottle until the Fill Straw is fully inserted. The end of the Fill Straw should be near the bottom of the contrast bottle.
7.Spike: prepare the bottle or container of contrast and/or saline solution. Push the bottle or bag onto the Filling Device until the seal is punctured.
8.NOTE: Use Fill Straw or equivalent device to reduce the volume and size of air bubbles drawn into the syringe during filling. It is more difficult to remove the air bubbles if you use smaller diameter tubes, such as catheter-over-needle, or a tube longer than 10 in.(25cm.)
9.Aspirate contrast media into the syringe.
10.If the syringe has dot indicators use them to help you detect the presence of contrast media in the syringe. Verify that the Syringe disposable dot indicators are round in the filled portion of the syringe. The rounded shape of the dot indicators varies according to the type of contrast media, but an oblong shape indicates the presence of air. Rounded dot indicators do not indicate the total absence of air bubbles in the syringe tip.
* Refer to the injector operation manual for further instructions.
Expelling Air & Attaching the Connector Tubing
1.After you fill the syringe, you must expel all air from the syringe and then attach the connector tubing. To do so:
2.Remove the filling device and expel air from the syringe. Do not hit the syringe to remove air bubbles. Reverse the plunger 3 to 5 ml, then, if applicable, rock the injector head on the pivot to dislodge the bubbles. Expel the remaining air.
3.If you are using a Y low pressure connector tubing, attach shorter side of the Y to the contrast syringe and the longer side of the Y to the saline syringe. Do not reverse the piston plunger after you have attached the tubing. 
4.Verify that the tubing is not kinked or obstructed.
5.(If your injector does not have a manual knob, proceed to Step 6.) Use the manual knob to advance the syringe plunger to provide 
6.Prime the connector tubing and make certain that the air is expelled. 
7.Verify that all the air has been expelled from the syringe and fluid path. 
8.Attach the connector tube to the vascular entry device.
9.Tilt the injector head (or syringe interface module) down. 
* Refer to the injector operation manual for further instructions.
Removing the Syringe
10.To detach the syringe when the procedure has been completed, Remove it from the injector head. Discard all used components.
* Refer to the injector operation manual for further instructions.
11.Check the integrity of each primary package before use!
12.Confirm syringe model and injector model compatibility per Table 1 above.
13.Remove the syringe from the package. Attach the syringe to the injector according to the injector instructions for use.
14.Use the injector to push the piston of the syringe to the front of the barrel.
15.Remove the sheath from the conical fitting. Assemble the J shape tube/ spike on the conical fitting of the syringe.
16.Draw the required contrast media or saline into the syringe at the lowest speed of the injector to prevent air leakage.
17.Remove the J shape tube/spike from the syringe; discard it per the hospital or local regulations. Do not reuse!
18.Remove the protective cap from the conical fitting of the high pressure tube. Attach the tube to the syringe.
19.Attach the I.V. catheter or contrast media catheter to the other conical fitting of the high pressure tube. 
20.Expel the air in the catheter and tube. 
21.Inject the contrast media or saline in accordance with the instruction for use of the injector.
22.After the injection, disconnect the I.V. catheter or contrast media catheter and the high pressure tube.  Remove the syringe from the injector. 
23.Discard the syringe, tube and catheter immediately per hospital or local regulations.

More information,please contact us kindly.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
23600000 RMB
Plant Area
5000 square meters