Description
Boon Sterile High-pressure Angiographic Syringes used for Enhancing scan imaging, compatible with various different CT MRI DSA injectors.
helping doctors find lesions more clearly and quickly. Contrast agents and saline are injected through various CT MRI DSA contrast media injectors. Mainly used in the hospital radiology department and medical imaging department.
Boon Angiographic syringes have covered the world's main popular contrast media injectors models, such as Medrad, LF, Medtron, Nemoto, Bracco, SINO, SEACROWN.
Features
Specification
Contain: 2-200ml CT syringe, 1-1800mm Patient tube with Y connector, 2-J tubes / Large spikes
Quality Control
Boon high-pressure syringes strictly implement ISO9001 and ISO13485 quality management systems and are produced in 100,000-level purification workshops. Quality is the life of an enterprise.
Boon is always following the quality policy of "Pursuing Product Excellence Ensuring Public Health"
Certification
Label & Package
Package
1. Individual package: Blister package, the label made by Tyvek paper, PS blister box.
2. 50kits per case, 10kits each layer, total 5 layers.
3. OEM is Acceptable.
Sea Freight
Reference Data (Sea Freight) |
Container |
20GP |
40GP |
40HQ |
45HQ |
Area(M3) |
25 |
54 |
68 |
86 |
Quantity(Case) |
260 |
440 |
550 |
700 |
Certification
Company Profile
Compatible Sheet
Model (Syringe) |
Volume (ml) |
Compatible Angiographic Injector |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following MEDRAD Injector models |
100101 |
200ml |
MCT & MCT plus CT, Vistron CT, En Vision CT |
100103 |
200ml |
Medrad Stellant-S |
100113 |
200/200ml |
Madrad Stellant-D(Dual) |
200101 |
65/65ml |
Spectris |
200102 |
65/115ml |
Solaris |
300101 |
150ml |
Mark V |
300105 |
130ml |
Mark III & Mark IV |
300108 |
150ml |
Mark VII |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following LIEBEL - FLARSHEIM Injector models |
100104 |
200ml |
CT 9000 & CT9000 ADV Optivantage |
100114 |
200/200ml |
CT 9000 & CT9000 ADV Optivantage(Dual) |
200103 |
60/60ml |
Optistar LE, Elite |
300103 |
150ml |
ILLUMENA |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following EZEM Injector models |
100111 |
200ml |
Empower CT |
100121 |
200/200ml |
Empower CT (Dual) |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following NEMOTO Injector models |
100108 |
200ml |
A-60 CT |
100109 |
100ml |
A-25 CT |
100118 |
200/200ml |
A-60 CT (Dual) |
100119 |
100/100ml |
A-25CT (Dual) |
200104 |
60ml/60ml |
Sonic Shot 50 |
300102 |
125ml |
120S |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following MEDTRON Injector models |
100112 |
200ml |
Medtron |
200105 |
60/60ml |
Medtron(Dual) |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following IMAXEON Injector models |
100110 |
200ml |
Imaxeon Salient |
100120 |
200ml |
Imaxeon Salient (Dual) |
The Sterile High-pressure Angiographic Syringes for Single-use models listed below are compatible with the following others injector models |
100102 |
200ml |
CHINA SINO-D-S |
100105 |
200ml |
CHINA ANKE ASA200 |
100115 |
200/200ml |
CHINA SINO-D (Dual) |
100106 |
200ml |
CHINA SEACROWN ZENITH-C20 |
100116 |
200/200ml |
CHINA SEACROWN ZENITH -C22 (Dual) |
100107 |
100ml |
CHINA SEACROWN ZENITH-C11/C10 |
100117 |
100/100ml |
CHINA SEACROWN ZENITH-C11 (Dual) |
200106 |
65/65ml |
CHINA SEACROWN ZENITH-C60 (Dual) |
200107 |
65ml |
CHINA SEACROWN ZENITH-C60 |
300104 |
150ml |
CHINA SEACROWN ZENITH-H15 |
Instructions for Use
Syringe Filling
1.NOTE: One person should fill and arm the injector. If you must change the injector operator, be certain that the second operator verifies that the syringe is properly filled and that any air is eliminated.
2.Tilt the injector head (or the syringe interface module) up.
3.Advance the plunger to full forward position.
4.Remove the protective cover from the syringe luer tip and attach a sterile filling device onto the tip of the syringe. Fill straw, or spike.
5.Transfer the contrast media into the syringe by one of following methods:
6.Fill Straw: raise the contrast bottle until the Fill Straw is fully inserted. The end of the Fill Straw should be near the bottom of the contrast bottle.
7.Spike: prepare the bottle or container of contrast and/or saline solution. Push the bottle or bag onto the Filling Device until the seal is punctured.
8.NOTE: Use Fill Straw or equivalent device to reduce the volume and size of air bubbles drawn into the syringe during filling. It is more difficult to remove the air bubbles if you use smaller diameter tubes, such as catheter-over-needle, or a tube longer than 10 in.(25cm.)
9.Aspirate contrast media into the syringe.
10.If the syringe has dot indicators use them to help you detect the presence of contrast media in the syringe. Verify that the Syringe disposable dot indicators are round in the filled portion of the syringe. The rounded shape of the dot indicators varies according to the type of contrast media, but an oblong shape indicates the presence of air. Rounded dot indicators do not indicate the total absence of air bubbles in the syringe tip.
* Refer to the injector operation manual for further instructions.
Expelling Air & Attaching the Connector Tubing
1.After you fill the syringe, you must expel all air from the syringe and then attach the connector tubing. To do so:
2.Remove the filling device and expel air from the syringe. Do not hit the syringe to remove air bubbles. Reverse the plunger 3 to 5 ml, then, if applicable, rock the injector head on the pivot to dislodge the bubbles. Expel the remaining air.
3.If you are using a Y low pressure connector tubing, attach shorter side of the Y to the contrast syringe and the longer side of the Y to the saline syringe. Do not reverse the piston plunger after you have attached the tubing.
4.Verify that the tubing is not kinked or obstructed.
5.(If your injector does not have a manual knob, proceed to Step 6.) Use the manual knob to advance the syringe plunger to provide
6.Prime the connector tubing and make certain that the air is expelled.
7.Verify that all the air has been expelled from the syringe and fluid path.
8.Attach the connector tube to the vascular entry device.
9.Tilt the injector head (or syringe interface module) down.
* Refer to the injector operation manual for further instructions.
Removing the Syringe
10.To detach the syringe when the procedure has been completed, Remove it from the injector head. Discard all used components.
* Refer to the injector operation manual for further instructions.
11.Check the integrity of each primary package before use!
12.Confirm syringe model and injector model compatibility per Table 1 above.
13.Remove the syringe from the package. Attach the syringe to the injector according to the injector instructions for use.
14.Use the injector to push the piston of the syringe to the front of the barrel.
15.Remove the sheath from the conical fitting. Assemble the J shape tube/ spike on the conical fitting of the syringe.
16.Draw the required contrast media or saline into the syringe at the lowest speed of the injector to prevent air leakage.
17.Remove the J shape tube/spike from the syringe; discard it per the hospital or local regulations. Do not reuse!
18.Remove the protective cap from the conical fitting of the high pressure tube. Attach the tube to the syringe.
19.Attach the I.V. catheter or contrast media catheter to the other conical fitting of the high pressure tube.
20.Expel the air in the catheter and tube.
21.Inject the contrast media or saline in accordance with the instruction for use of the injector.
22.After the injection, disconnect the I.V. catheter or contrast media catheter and the high pressure tube. Remove the syringe from the injector.
23.Discard the syringe, tube and catheter immediately per hospital or local regulations.
FAQ
1. Is Boon a real manufacturer?
B: Yes, definitely. Founded in 1990, already 32 years history, Welcome to visit us.
2. How long is the delivery time?
B: Depending on your needs, if you could accept Multiple language labels, we could deliver 2-3 days after payment confirmation.
3. Could the syringe kit truly use for Children?
B: Only the syringe after EO releases strongly could use for the children who get the 10KGs+ weight.
4. How could we get quick contact with you?
B: Just inquiry in Made-in-china platform, here is Boon Official MIC site, we will contact you in 24 hours after receiving your message.